SP125 Limited

             22 Walker Wood,  Baildon,  Shipley,  West Yorkshire,  BD17 5BE,  England

             Telephone 01274 583231      steve@sp125racing.com      Mobile 07738 626165

 

 

      www.sp125racing.com

 

           RS125 Setting Data & Maintenance Information

 

          RS125 / RS250 Settings using Detonation Counters

 
 
 
TECHNICAL
Settings using detonation counters
  RS125R / RS250R
Detonation
  Detonation will occur at before or after the maximum output speeds (if peak speed is 12500 rpm, detonation occurrence ranges from 12250 to 12750 rpm). Detonation seldom occurs outside these speed ranges.
As shown below, 5th and 6th gears provide less acceleration than 1st and 2nd gears where there is extended use of these detonation range speeds. For this, circuits with more acceleration and deceleration frequencies give less detonation occurrence than circuits where there is extended use of wide open throttle operation using 5th and 6th gears.
Frequent use of low ratio and 12750 rpm and over resulting from ratio choices will control propensity toward detonation. Also, distinct behaviour of driving will result in less detonation associated with partial throttle opening.
 
 

 

 
In the engine output characteristics figure shown above, peak speed are changing, depending on wide open throttle to partial throttle. Accordingly, detonation occurrence ranges may vary with throttle opening. Detonation may suddenly take place when returning throttle from fully wide-open throttle at 11000 rpm.
 
Counting at fully wide open ranges tends to lead to damages, but counting at partial range will lead to less damages. Accordingly, you should find your base because counts are different from rider behaviours to course lay outs.
Criteria for detonation counter
  Many riders seem to have detonation counters fitted on their machines for information used for settings. Both the RS125R and RS250R should have detonation counter numbers of one to two per kilometre as criteria.
In the case of the Suzuka Circuit with one lap length of about 6 kilometre, the criteria for the counter will be 12 per lap.
As mentioned before, detonation will occur in needle ranges such as partial throttles as well as the fully open main region. You should check where values gained from the counters occur. One to two/km in the main region are recommended.
Countermeasures against detonation
 
Even rich settings may lead to detonation for the following reasons.
Damaged pistons or heads are found at the engine maintenance.
(CAUSE)
High secondary compression
Advanced ignition timing
Chambers or silencers have been replaced or have deformation or dents
Secondary air is breathed in
Fuel strainers or tank one-way valves are clogged
Old gasoline is used
JET NEEDLE, SLOW JET, or PWJ other than MAIN JET are lean Too early power jet cut
No engine damage is found but too may count numbers found.
(CAUSE)
Defective tightening torque for counter sensors
Counter sensor or counter body is picking up vibration
Counter cord is picking up electrical noises
Disconnected counter cord
Lack of counter voltage
Previously damaged pistons or heads are used
The engines is damaged, but no count found.
(CAUSE)
Sensor tightening torque is below specified
Failed sensor/counter
Disconnected coupler or ingress of water
Defective carburetor (check float movement)

 

SPARK PLUG / DETONATION SENSOR TIGHTENING TORQUE = 2.5 Kgf.m

 

 
 
Return To RS125 HRC Setting Data & Maintenance Information
 
Return To sp125racing.com Homepage
 
 
 
 

SP125 Limited Disclaimer

Honda, HRC and all other parts supplied by the SP125 Limited are not guaranteed when used in competition events.
As such, it is a condition of our making all parts available that it is solely the decision of each individual, rider, team member or team whether they choose to use any part supplied and in doing so, absolve the manufacturer and SP125 Limited of any or all such claims, including damage to equipment and/or injury to personnel irrespective of how caused.
All parts remain property of SP125 Limited until paid for in full.

All 'special order' parts, that are ordered specially under the instruction of the customer, are non returnable and non refundable.